TM4 | Simulator Room Dimension Requirements

These specifications will give you a strong guide on what is required and are the minimum dimensions of a space in order to be suitable for a Trackman Simulator setup with one bay. We hope this guide will be useful, but if you have any questions relating to installing a Trackman Simulator, please submit a support ticket here.

Trackman 4 uses Dual Radar Technology with Optically Enhanced Radar Tracking (OERT). This means that the impact is measured by using a combination of both optical and radar tracking.

Detailed_Room_Dimensions.JPG

 

Room Height (Floor to Ceiling)

  • Optimal : 11ft (3.35m)
  • Minimum : 9ft (2.75m)

Ball Flight Distance (Hitting Area to Impact Screen)

  • Optimal : 12ft (3.65m)
  • Minimum : 10ft (3m)

Ball To Trackman (Hitting Area to Trackman)

  • Optimal : 7ft (2.1m)
  • Minimum : 6ft (1.8m)
  • Maximum : 9ft 6in (2.9m)

Allow 1ft (30cm) of space directly behind the impact screen

For further information on specific OERT lighting information & requirements for your Trackman Simulator, see this article: Trackman 4 Simulator OERT Lighting Requirements

Didn't find what you were looking for?

Search